240-60
By-Pass Foam Eductor
60 GPM flow - By-Pass allows for water only operations at
lower inlet pressures - Positive setting metering valve(0, 1/2,
1, 3, & 6%) - 1.5" or 2.5" NHT free swivel inlet -
1.5" NHT male outlet - Length, 17.25" - Weight 20.5
lbs. - Finish red acrylic/urethane enamel with chrome plated
trim |
|
240-95
By-Pass Foam Eductor (Not Shown)
Same as 240-60 except 95 GPM flow |
|
240-125
By-Pass Foam Eductor (Not Shown)
Same as 240-60 except 125 GPM flow |
|
241-30
Inline Foam Eductor (Not Shown)
30 GPM flow - Infinite setting metering valve(0 thru 6%) -
1" or 1.5" NHT free swivel inlet - 1" NHT male
outlet - Length 8.375" - Weight 4.5 lbs. - Finish red
acrylic/urethane enamel with chrome plated trim |
|
 |
241-60
Inline Foam Eductor
60 GPM flow - Positive setting metering valve( 0, 1/2, 1, 3,
& 6%) - 1.5" or 2.5" NHT free swivel inlet -
1.5" NHT male outlet - Length 11.75" - Weight 9.5 lbs.
- Finish red acrylic/urethane enamel with chrome plated trim |
|
241-95
Inline Foam Eductor (Not Shown)
Same as 241-60 except 95 GPM flow |
|
241-125
Inline Foam Eductor (Not Shown)
Same as 241-60 except 125 GPM flow |
|
241-250
Inline Foam Eductor Not Shown
Similar to 241-60 except 250 GPM, a 2.5" NHT free swivel
inlet, and a 2.5" NHT male outlet - Length 16" -
Weight 16.75 lbs. |
|
 |
 |
|
Infinite
Setting Valve |
Positive
Setting Valve |
|
Operating
Pressure for Eductors
|
|
These
eductors are designed to achieve rated flow with an inlet
pressure of 200 psi. They will operate at lower inlet pressures
than this, but the flow rate and percentage rate will be
affected. For more technical information on these eductors, call
for our operating and maintenance instructions(Form No.
EB-98069).
|
|
Check List if
Eductor Fails to Pick Up Foam
|
|
These
eductors are very basic in design and very easy to operate.
However, there are many other conditions and situations that can
cause the eductor to fail in picking up foam concentrate. If
this happens check the following: |
|
- Mismatched nozzle
- Partially closed nozzle
- Clogged nozzle
- Hose lay too long
- Metering valve closed
- Nozzle elevated too high
|
- By-pass valve open
- Ball check stuck
- Metering valve clogged
- Plugged pickup screen
- Metering valve set
improperly
- Kink in hose
|
|
There
are occasions in fire suppression when greater expansion rates
of foam solution are needed; such as when polar solvent fuels
are involved; when using protein or fluoroprotein foam; or when
securing a spill. For these special situations a foam aeration
tube can be quickly and easily attached to most of our
combination fog nozzles in order to acheive a higher expansion
rate of the foam solution; up to 15:1 in some cases. |
|
244
Foam Aeration Tube
For adding more air to foam solution in order to achieve
greater expansion rate - Quickly attaches to SFL,
SFL-G, SFL-GN, and SFL-N - Durable, lightweight Elk-O-Lite
construction - Cast finish with nylon cord wrap - Length:
40.5" - Weight: 4.5 lbs. |
|
246
Foam Aeration Tube
For adding more air to foam solution in order to achieve
greater expansion rate - Quickly attaches to SM-10F,
SM-10FG, SM-20F, SM-20FG, TSM-20F, 4000-10, 4000-13, 4000-14,
4000-16, 4000-17, SFL-B, SFL-BG, SFM, SFM-G and TSFM -
Durable, lightweight Elk-O-Lite construction - Cast finish with
nylon cord wrap - Length: 30.25" - Weight: 4.75 lbs. |
|
246S
Foam Aeration Tube
Similar to 246 except shorter, lighter, and with built-in
Hydroverter - Length: 15.87" - Weight: 3.80 lbs. |
|
247
Foam Aeration Tube
For adding more air to foam solution in order to achieve
greater expansion rate - Quickly attaches to DSM-30F,
SM-30F, SM-30FG, TSM-30F, 4000-20, 4000-22, 4000-23, 4000-24,
and 4000-26 |
|
247S
Foam Aeration Tube
Similar to 247 except shorter, lighter, and with built-in
Hydroverter - Length: 15.87" - Weight: 3.80 lbs. |
|
|
|
|